On the nth day of Christmas, CMS gave to me: Ligature risks revisited

As you will no doubt recall, back at the beginning of November, The Joint Commission released guidance relative to survey expectations and ligature risks, splitting things into guidance for behavioral health units/hospitals and then some separate items for expectations in non-behavioral health settings (emergency departments, inpatient units). The information release indicated that there were some folks from CMS involved in the (what will apparently be ongoing) discussion on what healthcare organizations can expect over the next little while as the challenges of managing all variations of the behavioral health patient population. What wasn’t clear at the time (at least to me—and it’s still not) was whether CMS’ participation in that process could be interpreted as an at least tacit endorsement of the guidance statements.

And now (well, this past week), CMS issued its own thoughts relative to its expectations, including indication that more will be forthcoming (in approximately six months’ time, so let’s just say sometime next summer). The Survey & Certification memorandum outlines the current slate of expectations (yours and theirs), starting with the pretty much unassailable notion that: “Ligature risks compromise Psychiatric Patients’ right to receive care in a safe setting.” I think we can all agree that that is a reasonable assertion with which to start a conversation.

The memo also goes on to outline the CMS definition of a ligature risk: “(a) ligature risk (point) is defined as anything which could be used to attach a cord, rope, or other material for the purpose of hanging or strangulation. Ligature points include shower rails, coat hooks, pipes, and radiators, bedsteads, window and door frames, ceiling fittings, handles, hinges and closures.” For me, the only surprise was that the example list didn’t say “include, but are not limited to.” I’m used to the regulatory rapscallions leaving themselves an “out” when it comes to this kind of stuff. While the list is pretty comprehensive, I think it stops a little short of all-inclusive, but perhaps as a function of the designated behavioral health environment, it will do. Which leads to the next highlight: this particular guidance is “primarily aimed at Psychiatric units/hospitals.” I guess that means that guidance for non-BH areas like regular emergency departments and acute-care hospital inpatient units that might have to manage behavioral health patients—maybe in the summer, but not really clear on that. It will be interesting to see how future guidance will dovetail (or not) with the TJC stuff.

So, as we wait for the next installment, it appears that it will be left in the hands of the folks on the ground (CMS regional offices, state survey agencies, accreditation organizations) to “the identification of ligature and other safety risk deficiencies, the level of citation for those deficiencies, as well as the approval of the facility’s corrective action and mitigation plans to minimize risk to patient safety and remedy the identified deficiencies.” At least for the moment, we know how TJC is going after this issue, but everything else is somewhat in the land of gray.

A couple of other items covered include time frame for correction of deficiencies (you have to fix things in the time frame identified by the surveying body, unless it is determined that it is not reasonable to expect compliance within the designated time frame, then only CMS can grant additional time for correction); the specific direction that ligature risks do not qualify for Life Safety Code® (LSC) waivers (because ligature risks are not LSC deficiencies); and if you do get to take additional time for corrective actions, monthly electronic progress reports—including substantiating evidence of progress towards compliance—will be the task. It would seem that the monthly check-in, particularly as a function of providing “substantiating evidence of progress” will help to keep the fires of progress burning bright in the hearts and minds of folks charged with making the necessary corrections. As a function of that, I’ve heard of some anecdotal accounts of surveyors indicating that there is a six-month grace period for corrective actions as long as you can substantiate that the corrections will take that long, but the word from Chicago is that is not the case. I have certainly witnessed long lead times for procurement of ligature-resistant door hardware and such, but that’s not enough to delay the reporting of progress process.

The Survey & Certification memorandum includes an attachment that outlines the current guidance to surveying agencies/organizations. I would encourage you all to give that a thorough look-see (and perhaps a dramatic reading instead of the traditional “’Twas the night before Christmas”—bet it puts the kiddies to sleep PDQ). Doubtless, I will weigh on some of the particulars as they leap out at me (much like those leaping lords) in the coming weeks, but I think I’ve gone on long enough for the moment. That said, I will leave you with these two passages from the guidance attachment:

  •  “In order to provide care in a safe setting, hospitals must identify patients at risk for intentional harm to self or others, identify environmental safety risks for such patients, and provide education and training for staff and volunteers.”

 

  • “Although all risks cannot be eliminated, hospitals are expected to demonstrate how they identify patients at risk of self-harm or harm to others and steps they are taking to minimize those risks in accordance with nationally recognized standards and guidelines.”

Certainly nothing we haven’t talked about in the past in regards to an endless supply of subjects, but kind of interesting to see this included in a missive from the palace…

Do you miss the safety professional you once had time to be?

I think we can agree that things in the safety world are moving along at a pretty good clip, particularly when it comes down to ensuring ongoing compliance with the various and sundry nuances that are flowing forth from the regulatory firehose. Now I’m sure are those of you that would like nothing better than to pore over the various and sundry code handbooks to figure out best to apply the latest changes to your practices/organizations. But I can tell you this: That’s getting to be very close to a full-time job all on its own—and too many of the current generation of survey findings have as much to do with managing the behaviors of staff at point of care and point of service as they do in figuring out what interpretation is going to win the day going forward. So, as I hear of some findings that I would tend to characterize as “frequently cited,” I want to make sure that I share them with you. This week, here’s a couple of items relating to emergency power:

Under the standard dealing with the setup of your emergency power system, there is a “new” performance element that requires a remote manual stoop station (with identifying label) “to prevent inadvertent or unintentional operation.” The performance element also points toward having a remote annunciator (powered by a storage battery) outside the EPS location. Anecdotally, I understand this is coming up with a fair frequency out in California, so probably worth a look-see for your gen sets.

Under the standard dealing with the inspection, testing, and maintenance of emergency power systems, the weekly inspection (and associated documentation) finally shows up as a specific performance expectation, as does the annual fuel quality test (to ASTM standards, so please make sure that your documentation of those activities is up to date).

As a final note for this week; some updates to the behavioral healthcare Life Safety chapter considerations, mostly shifting the Life Safety Code® chapter references from Chapter 26 (Lodging or Rooming Houses) in the 2000 edition to Chapter 32/33 (new and Existing Residential Board and Care occupancies). The changes impact “small” facilities that provide sleeping arrangements for four to 16 individuals. I don’t see anything particularly substantive, or indeed troubling, in the new stuff, but if you feel otherwise after checking it out, then please sing out loud and clear.

ADA vs. LSC: Projecting into the Future—Are You Ready to Rumble?

One of the nagging things (at least for me) that’s been looming in the background is CMS’ statement (and restatement, with a side of reiteration) emphasizing that the Life Safety Code® (LSC) is not an accessibility code and, thus, does not ensure compliance with the Americans With Disabilities Act (ADA). You can find that statement and some other funky stuff here.

The web page also includes some specific considerations that I suspect that you will find of considerable interest (well, it did for me) in that it appears to represent some sense of how the ADA vs. LSC joust is going to manifest itself in the field. The following are the relevant sections, with a link to the individual paragraphs from the Federal Register:

SECTIONS 18.2.3.4(2) AND 19.2.3.4(2)—CORRIDOR PROJECTIONS

This provision requires noncontinuous projections to be no more than 6 inches from the corridor wall. In addition to following the requirements of the LSC, healthcare facilities must comply with the requirements of the ADA, including the requirements for protruding objects. The 2010 Standards for Accessible Design (2010 Standards) generally limit the protrusion of wall-mounted objects into corridors to no more than 4 inches from the wall when the object’s leading edge is located more than 27 inches, but not more than 80 inches, above the floor. See Sections 204.1 and 307 of the 2010 Standards, available at http://www.ada.gov/​regs2010/​2010ADAStandards/​Guidance2010ADAstandards.htm [2] (“2010 Standards”). This requirement protects persons who are blind or have low vision from being injured by bumping into a protruding object that they cannot detect with a cane. (https://www.federalregister.gov/d/2016-10043/p-78)

Although the LSC allows 6-inch projections, under the ADA, objects mounted above 27 inches and no more than 80 inches high can only protrude a maximum of 4 inches into the corridor beyond a detectable surface mounted less than 27 inches above the floor (except for certain handrails which may protrude up to 41/2″). See section 307 of the 2010 standards for requirements for handrails and post-mounted objects. CMS intends to provide technical assistance regarding strategies for how to avoid noncompliance with the ADA’s protruding objects requirement, as well as how to modify non-compliant protruding objects.) (https://www.federalregister.gov/d/2016-10043/p-80)

SECTIONS 18.2.3.4 AND 19.2.3.4—CORRIDORS

This provision allows for wheeled equipment that is in use, medical emergency equipment not in use, and patient lift and transportation equipment be permitted to be kept in the corridors for more timely patient care. This provision also allows facilities to place fixed furniture in the corridors, although the placement of furniture or equipment must not obstruct accessible routes required by the ADA. See section 403.5 of the 2010 Standards. (https://www.federalregister.gov/d/2016-10043/p-88)

So, it appears that we may be looking at some changes of fixtures, etc. (including fire extinguishers—lots of those wall-mounted lovelies floating around, not to mention hand sanitizer dispensers) and a re-think of how we’re positioning furniture in corridors—should be an interesting ride. A hearty thanks to Kevin Kozlowski, president of Oval Brand Fire Products for planting the seed that germinated into this week’s missive. Among other things, Kevin and his folks manufacture a fire extinguisher that meets ADA requirements for wall projections.

If you’d like me to discuss a particular topic, please feel free to kick something my way. I figure any question one person has, the likelihood of others having the same or similar question it pretty strong, so don’t be afraid.

If brevity is the soul of wit…

Hope everyone enjoyed a festive and (most importantly) safe Independence Day—with any luck, today (July 5) does not mark the end of summer (as some do say) so much as it marks the beginning of the end of spring (up here in the Northeast, spring was loath to depart, but it does seem that pre-autumn weather has finally made a commitment to spending some time in the northern hemisphere).

I was looking recently at past blog posts for a reference to the CMS stance on law enforcement interactions with patients as a function of restraints and patient rights—always a fun topic—and I noted that the posts used to be a mite briefer than tends to be the case of late. (You can be the judge of whether my decline in brevity has left me soulless or witless.) I absolutely recognize that there’s been a lot of stuff to cover over the past 18 months with the firestorms of compliance that swept the healthcare environment, which has (no doubt) promoted some of the “volume” of bloggery. But it has caused me to wonder whether I am consuming the compliance elephant in sufficiently small bites to be of use to you folks out there in the field. As near as I can tell, the purpose of this whole thing (as much as I enjoy having a place to pontificate) is to provide information and thoughts on what is happening at the moment to you, my faithful audience of safety folk. And (as near as I can tell) it never hurts to ask one’s audience whether this works for you—please feel free to give me an e-dope slap if you think the “Space” has gone intergalactic in a less-than-useful way. At any rate, I am going to experiment with smaller bites of information in the coming weeks so you’ll have more time for other things—perhaps outdoors…

As far as news goes, things are relatively quiet as we observe the anniversary of CMS’s adoption of the 2012 Life Safety Code. Hopefully you all have done your NFPA 99 risk assessments; polished off those door inspections and are speeding towards the completion of activities relating to initial compliance with the Emergency Preparedness Final Rule. Health Facilities Management This Week discussed some prepublication EC/LS standards relating to the testing of emergency lighting systems; inspection and testing of piped medical gas and vacuum systems; and updating pertinent NFPA code numbers. The pre-pub stuff is aimed at behavioral health care, laboratory, nursing care center, and office based surgery accreditation programs. You can find the details here: https://www.jointcommission.org/prepublication_standards_%E2%80%93_standards_revisions_to_environment_of_care_and_life_safety_chapters_related_to_life_safety_code_update_/

(I guess some of those links are about as brief as I am…)

Thanks, as always, for tuning in—I really appreciate having you all out there at the other end of the interweb…see you next week!

Point the finger (doesn’t matter which)

Or extend your hand?

First up, as a general rule of thumb (which could be one of the pointed fingers represented above, unless you don’t think a thumb is a finger), when CMS identifies an implementation date that is in the future, I think that we can safely work towards being in full compliance with whatever the Cs are implementing—on that implementation date. Apparently there’s been enough confusion (not really sure who may or may not have been confused, but sometimes it’s like that) for CMS to issue something of a clarification as to what is expected to be in place by November 15, 2017, which means education and exercises (and any other pesky items in your EM program that didn’t quite synch up with the final rule on emergency preparedness for healthcare organizations). Since this is very much brave new world territory when it comes to how (though perhaps the correct term would be “how painfully”) CMS is going to administer the final rule as a function of the survey process. I think it initially, unless we hear something very specific otherwise, means that we need to be prepared to meet the full intent of the language (making sure that you have trained/educated “all” staff; making sure that you participated in a community-wide exercise of some level of complexity) until these things start to sort out. My gut tells me that if they were going to engage in any more exculpatory/explanatory/clarifying communications, it would have been included in the above-noted transmission. And while I have little doubt that there will be some variability (states do not necessarily coordinate response) as to how this all pans out in the field, the education of “all” staff and participation in the communitywide exercise deal seem to be pretty inviolable. Certainly there have been instances in the past in which healthcare organizations have struggled to coordinate exercises with the local community(s), but my fear is that if you fall short on this, you will need to have a very compelling case of why you weren’t able to pull off a coordinated exercise. Community finances and fiscal years and local emergency response hegemony are all contributing factors, to be sure, but where you could “sell” that as a reason for not dancing with the locals to some of the accreditation organizations, I’m thinking that (as is usually the case) reasonableness and understanding might not be the highlights of any discussion with the feds and those that survey on their behalf. From what I’ve seen in the field, when it comes to CMS and the survey process, you are either in compliance or you are not in compliance and there is very little gray in between. Community drill done—compliant! Community drill not done—not compliant! Wouldn’t it be nice if life were always that simple?

At any rate, just to use this a reminder that the first anniversary of the 2012 Life Safety Code® is coming up—make sure you get all that annual testing and such out of the way—and don’t forget to make sure that all your fire alarm and suppression system documentation includes the correct version of the applicable NFPA code used for testing. I am dearly hoping to retire EC.02.03.05 from the most frequently cited standards ranks and while I fear the worst with this change. (To my mind, getting tagged for having the wrong NFPA year on the documentation would pretty much suck—please excuse my coarse language—but sucking is exactly what that type of finding would do.)

Do you know the way to TIA?

Last week we touched upon the official adoption of a handful of the Tentative Interim Agreements (TIA) issued through NFPA as a function of the ongoing evolution of the 2012 edition of the Life Safety Code® (LSC). At this point, it is really difficult to figure out what is going to be important relative to compliance survey activities and what is not, so I think a brief description of each makes (almost too much) sense. So, in no particular order (other than numerical…):

  • TIA #1 basically updates the table that provides the specifications for the Minimum Fire Protection Ratings for Opening Protectives in Fire Resistance-Rated Assemblies and Fire-Rated Glazing Markings (you can find the TIA here). I think it’s worth studying up on the specific elements—and perhaps worth sharing with the folks “managing” your life safety drawings if you’ve contracted with somebody external to the organization. I can tell you from personal experience that architects are sometimes not as familiar with the intricacies of the LSC—particularly the stuff that can cause heartburn during surveys. I think we can reasonably anticipate a little more attention being paid to the opening protectives and the like (what, you thought it couldn’t get any worse?), and I suspect that this is going to be valuable information to have in your pocket.
  • TIA #2 mostly covers cooking facilities that are open to the corridor; there are a lot of interesting elements and I think a lot of you will have every reason to be thankful that this doesn’t apply to staff break rooms and lounges, though it could potentially be a source of angst around the holidays, depending on where folks are preparing food. If you get a literalist surveyor, those pesky slow cookers, portable grills, and other buffet equipment could become a point of contention unless they are in a space off the corridor. You can find the whole chapter and verse here.
  • Finally, TIA #4 (there are other TIAs for the 2012 LSC, but these are the three specific to healthcare) appears to provide a little bit of flexibility relative to special locking arrangements based on protective safety measures for patients as a function of protection throughout the building by an approved, supervised automatic sprinkler system in accordance with 19.3.5.7. Originally, this section of the LSC referenced 19.3.5.1 which doesn’t provide much in the way of consideration for those instances (in Type I and Type II construction) where an AHJ has prohibited sprinklers. In that case, approved alternative protection measures shall be permitted to be substituted for sprinkler protection in specified areas without causing a building to be classified as non-sprinklered. You can find the details of the TIA here.

 

I suppose before I move on, I should note that you’re probably going to want to dig out your copy of the 2012 LSC when looking these over.

As a quick wrap-up, last week The Joint Commission issued Sentinel Event Alert #57 regarding the essential role of leadership in developing a safety culture (some initial info can be found here). While I would be the last person to accuse anyone of belaboring the obvious (being a virtual Rhodes Scholar in that type of endeavor myself), I cannot help but think that this might not be quite as earth-shattering an issuance as might be supposed by the folks in Chicago. At the very least, I guess this represents at least one more opportunity to drag organizational leadership into the safety fray. So, my question for you today (and I suspect I will have more to say on this subject over the next little while—especially as we start to see this issue monitored/validated during survey) is what steps has your organization taken to reduce intimidation and punitive aspects of the culture. I’m reasonably certain that everyone is working on this to one degree or another, but I am curious as to what type of stuff is being experienced in the field. Again, more to come, I’m sure…

In season, out of season: What’s the difference?

…when you don’t know the reason…

Some Joint Commission goodness for your regulatory pleasure!

For those of you in the audience that make use of the online version of the Accreditation Manual, I would implore you to make sure that when you are reviewing standards and performance elements that you are using the most current versions of the requirements. I think we can anticipate that things are going to be coming fast and furious over the next few months as the engineering folks at TJC start to turn the great ship around so it is in accordance with the requirements of the 2012 edition of just about everything, as well as reflecting the CMS Conditions of Participation. To highlight that change, one example is the requirement for the testing of the fire alarm equipment for notifying off-site fire responders (decorum prevents me from identifying the specific standard and performance element, but I can think of at least 02.03.05.5 things that might serve as placeholders, but I digress); the January 1, 2017 version of the standards indicates that this is to occur at a quarterly frequency (which is what we’ve been living with for quite some time), but the January 9, 2017 version indicates that this is to occur on an annual basis, based on the 2010 edition of NFPA 72. In looking at the 2010 edition of NFPA 72, it would appear that annual testing is the target, but I think this speaks to the amount of shifting that’s going to be occurring and the potential (I don’t know that I would go so far as to call it a likelihood, but it’s getting there) for some miscommunications along the way. At any rate, if you use the online tool (I do—it is very useful), make sure that you use the most current version. Of course, it might be helpful to move the older versions to some sort of archived format, but that’s probably not going to happen any time soon.

Speaking of updates, last week also revealed additional standards changes that will be taking effect July 1, 2017 (get the detailed skinny here). Among the anticipated changes are the official invocation of NFPA 99 as guidance for the management of risk; some tweaking of the language regarding Alternative Equipment Management (AEM) program elements, including the abolition (?!?) of the 90% target for PM completion and replacing it with the very much stricter 100% completion rate (make sure you clearly define those completion parameters!); expansion of the ILSM policy requirements to include the management of Life Safety Code® deficiencies that are not immediately corrected during survey (you really have to look at the survey process as a FIFI—Find It, Fix It!—exercise); the (more or less) official adoption of Tentative Interim Agreements (TIA) 1, 2, and 4 (more on those over the next couple of weeks) as a function of managing fire barriers, smoke barriers, and egress for healthcare occupancies; and, the next (and perhaps final) nail in the coffin of being able to sedate patients in business occupancies (also to be covered as we move into the spring accreditation season). I trust that some of this will be illuminated in the upcoming issues of Perspectives, but I think we can safely say that the winds of change will not be subsiding any time soon.

Also on the TJC front, as we move into the 2017 survey year, those of you that will likely be facing survey, I encourage you to tune in to a webinar being presented on the SAFER (Survey Analysis For Evaluating Risk) matrix, which (aside from being transformative—a rather tall order and somewhat scary to consider) will be the cornerstone of your survey reports. We’ve covered some of the salient points here in the past (this is quickly becoming almost very nearly as popular a topic for me as eyewashes and general ranting), but I really cannot encourage you enough to give this topic a great deal of attention over the coming months. As with all new things TJC, there will be a shakedown cruise, with much variability of result (or this is my suspicion based on past experiences)—it is unlikely that this much change at one time is going to enhance consistency or it’s hard to imagine how it would/could (should is another matter entirely). At any rate, the next webinar is scheduled for Tuesday, March 7, 2017; details here.

Please remember to keep those cards and letters coming. It’s always nice to hear from folks. (It almost makes me think that there’s somebody out there at the other end of all those electrons…) Have a safe and productive week as we await the arrival of Spring!

 

Ring out, solstice bells!

And so we turn again to our perusal of the bounty that is the December issue of Perspectives and that most splendid of pursuits, the Clarifications and Expectations column. With the pending changes to the Life Safety (LS) chapter, it appears that we are in for a sequential review of said chapter, starting at the beginning (the process/program for managing LS compliance within your organization) and (at least for now) moving to a deep dive into the ILSM process in January—so stay tuned!

So let’s talk a little bit about the requirements relative to how the physical environment is designed and managed in such a manner as to comply with the Life Safety Code® (LSC). Previously, there were but four performance elements here: assigning someone to manage the process (assessing compliance, completing the eSOC, managing the resolution of deficiencies); maintaining a current eSOC; meeting the completion time frames for PFIs (did you ever think we would get to a point where we could miss those three letters?); and, for deemed status hospitals, maintaining documentation of AHJ inspections. For good or ill (time, as always, will be the final judge), the number of performance elements has grown to six with a slight modification to some of the elements due to the shift away from the eSOC as one of the key LS compliance documents and the evolution (mutation?) of our friend the Plan for Improvement into the Survey-Related PFI. With greater numbers of performance elements, I guess there will be a subsequent increase in confusion, etc. regarding interpretations (yours, mine, theirs) as to what it all means, which leaves us with requirements to:

 

  • Designate resources for assessing life safety compliance (evidence could be letters of assignment, position descriptions, documentation in meeting minutes); the survey process will include an evaluation of the effectiveness of the chosen method(s) for assessing LS compliance

 

  • Performance of a formal LS compliance assessment of your facility—based on time frames determined by your organization (big freaking hint: “best practice” would be at least annually); you can modify/adjust time frames based on the stability of your physical environment (if there’s not a lot going on, you might be able to reduce frequencies, though I haven’t been to too many places that didn’t have some activities that would impact LS compliance (Can you say “network cabling”? Sure you can!). Also, there is mention of the use of certain performance elements sprinkled throughout the LS chapter that will be used for any findings that are not specifically covered by the established performance elements. Clearly, there is a desire to leave no stone unturned and no deficiency unrecorded. Yippee!

 

  • Maintaining current and accurate life safety drawings; we’ve covered this in the past (going back to 2012), but there are still some folks getting tagged for having incomplete, inaccurate or otherwise less-than, life safety drawings. Strictly speaking, the LS drawings are the cornerstone of your entire LS compliance efforts; if they need updating and you have a survey any time in the next 12-18 months, you better start the leveraging process for getting them reviewed/revised. They don’t tell you how to do it, but if they’re not on auto-cad at this point, you better have a wizard for whatever program you are using. All they need to do is find one inconsistency and they can cite it…ugh! Check out the list in Perspectives and make sure that you can account for all of it.

 

  • Process for resolving deficiencies identified during the survey; we know we have 60 days to fix stuff found during the survey (and hopefully they don’t find anything that will take longer than that to resolve—I have this feeling that that process is going to be exceptionally unwieldy—and probably unyielding to boot). The performance element covers the process for requesting a time-limited waiver—that’s got to happen within 30 days of the end of the survey. Also, the process for requesting equivalencies lives here (if folks need a refresher on equivalencies, let me know and I will put that on the list for 2017 topics). Finally, this is also where the official invocation of the ILSM process as a function of the post-survey process is articulated (I think we covered that pretty thoroughly last week, but if you have questions—go for it!).

 

  • Maintaining documentation of any inspections and approvals (read: equivalencies) made by state or local AHJs; you’ve got to have this stuff organized and in a place you can lay your hands on it. Make sure you know how often your AHJs visit and make sure that you have some evidence of their “presence.” I think it also makes sense to keep any inspections from your property insurers handy—they are almost as powerful an AHJ as any in the process and you don’t want to run afoul of them—they can have a significant financial impact if something goes sideways with your building.

 

  • The last one is a little curious to me; I understand why they’re saying it from a global perspective, but it really makes me wonder what prompted specific mention. You can read the details of the language in Perspectives, but my interpretation of this is “don’t try any funny stuff when you’re renovating interior spaces and leave 4-foot corridor widths, etc., when you have clearly done more to the space than ‘updated finishes.’” I think this is the call-to-arms relative to having a good working knowledge of Chapter 43 of the 2012 You need to know what constitutes: repair; renovation; modification; reconstruction; change of use or occupancy classification; addition (as opposed to subtraction). Each of these activities can reach a degree/scope that “tips” the scales relative to the requirements of new versus existing and if you haven’t made that determination (sounds very much like another risk assessment, don’t it?) then you can leave it in the hands of a surveyor to apply the most draconian logic imaginable (I think draconian logic might be oxymoronic—and you can put the accent on either syllable), which will not bode well for survey success.

 

That’s the word from unity for this week; next week, we’ll check up on some Emergency Management doings in the wake of recent flooding, including some updates to the Joint Commission’s Emergency Management Portal (EMP?). Hope your solstice salutations are merry and bright until next time!

History shows again and again how standards (and EPs) point out the folly of men…

It’s beginning to look like the proofreaders in Chicago must be enduring some late nights watching the Cubs! I don’t know about you folks, but I rely rather heavily on the regular missives from The Joint Commission, collectively known as Joint Commission E-Alerts. The E-Alerts deliver regular packages of yummy goodness to my email box (okay, that may be a little hyperbolic) and yesterday’s missive was no exception. Well, actually, there was an exception—more on that in a moment.

While it did not get top billing in the Alert (which seems kind of odd given what’s been going on this year), the pre-publication changes to the Life Safety chapter of the accreditation manual have been revealed, including comparison tables between what we had in January 2016 and what we can expect in January 2017. Interestingly enough, the comparison tables include the Environment of Care (EC) chapter stuff as well (though the EC chapter did not merit a mention in the E-Alert), so there’s lots of information to consider (which we will be doing over the course of the next little while) and some subtle alterations to the standards/EP language. For example (and this is the first “change” that I noted in reviewing the 112 pages of standards/EPs), the note for EC.02.02.01, EP 9 (the management of risks associated with hazardous gases and vapors) expands the “reach” to specifically include waste anesthetic gas disposal and laboratory rooftop exhaust (yes, I know…very sexy stuff!). It does appear that at least some of the changes (tough to figure out the split between what is truly “new” and what is merely a clarification of existing stuff—check out the note under EC.02.03.05, EP 1 regarding supervisory signal devices because it provides a better sense of what could be included in the mix). Another interesting change occurs under EC.02.03.05 (and this applies to all the testing EPs) is that where previously the requirement was for the completion dates of the testing to be documented, now the requirement actually states that the results of the testing are to be documented in addition to the completion dates. Again, a subtle change in the language and certainly nothing that they haven’t been surveying to. Oh, and one addition to the canon is the annual inspection and testing of door assemblies “by individuals who can demonstrate knowledge and understanding of the operating components of the door being tested. Testing begins with a pre-test visual inspection; testing includes both sides of the opening.” At any rate, I will keep plowing through the comparison table. (Remember in the old days, it would be called a crosswalk. Has the 21st century moved so far ahead that folks don’t know what a crosswalk is anymore?)

The top billing in yesterday’s All Hallows Eve E-Alert (making it an Eve-Alert, I suppose) went to the latest installment in that peppiest of undertakings, the Physical Environment Portal. Where the proofreaders comment comes into play is that the Alert mentions the posting of the information relative to LS.02.01.30, (which happened back in August) but when you click on the link, it takes you to the update page, where the new material is identified as covering LS.02.01.35, so there is updated material, though you couldn’t really tell by the Alert. So, we have general compliance information for the physical environment folks, some kicky advice and information for organizational leadership, and (Bonus! Bonus! Bonus!) information regarding the clinical impact of appropriately maintaining fire suppression systems (there is mention of sprinkler systems, but also portable fire extinguishers). I’d be interested to see if anyone finds the clinical impact information to be of particular use/effectiveness. I don’t know that compliance out in the field (or, more appropriately, noncompliance) is based on how knowledgeable folks are about what to do and what not to do, though perhaps it is the importance of the fire suppression systems and the reasons for having such systems (Can you imagine having to evacuate every time the fire alarm activates? That would be very stinky.) that is getting lost in the translation. I have no reason to think that the number of findings is going to be decreasing in this area (if you’re particularly interested, the comparison table section on LS.02.01.35 begins on p. 80 of that document—any changes that I can see do appear likely to make compliance easier), so I guess we’ll have to keep an eye on the final pages of survey year 2016 and the opening of the 2017 survey season. Be still my beating heart!

I wanna know: Have you ever seen the rain?

In our intermittently continuing series on the (final!) adoption of the 2012 Life Safety Code®, we turn to the one area about which I have still the most concerns—the magic land of NFPA 99. My primary concern is that while NFPA 99 contains lots and lots of references to risk assessments and the processes therein, I’m still not entirely convinced that the CMS oversight of the regulatory compliance process is going to embrace risk assessments to the extent that would allow us to plot our own compliance courses. I guess I will have to warily keep my fingers crossed and keep an eye on what actually occurs during CMS surveys of the physical environment. So, on to this week’s discussion…

When considering the various and sundry requirements relating to the installation and ongoing inspection, testing and maintenance of electrical system components, one of the key elements is the management of risk associated with electrical shock in wet procedure locations. NFPA 99 defines a wet procedure location as “(t)he area in a patient care room where a procedure is performed that is normally subject to wet conditions while patients are present, including standing fluids on the floor or drenching of the work area, either of which condition is intimate to the patient or staff.”

Typically, based on that description, the number of areas that would “rule in” for consideration as wet procedure locations is pretty limited (and depending on the nature, etc., of the procedures being performed maybe even less limited than that). But in the modern age, the starting point for this discussion (and this is specifically provided for under section 6.3.2.2.8.4 of the 2012 edition of NFPA 99) is that operating rooms are to be considered wet procedure locations—unless a risk assessment conducted by the healthcare governing body (yow!) determines otherwise (all my yammering over the years about risk assessments is finally paying off—woo hoo!). By the way, there is a specific definition of “governing body”: the person or persons who have overall legal responsibility for the operations of a healthcare facility. This means you’re going to have to get your boss (and your boss’ boss and maybe your boss’ boss’ boss) to play in the sandbox on this particular bit of assessmentry.

Fortunately, our good friends at ASHE have developed a lovely risk assessment tool (this is a beta version) to assist in this regard and they will share the tool with you in exchange for just a few morsels of information (and, I guess, a pledge to provide them with some useful feedback as you try out the tool—they do ask nicely, so I hope you would honor their request if you check this out—and I really think you should). Since I’m pretty certain that we can attribute a fair amount of expertise to any work product emanating from ASHE (even free stuff!), I think we can reasonably work with this tool in the knowledge that we would be able to present it to a surveyor and be able to discuss how we made the necessary determinations relative to wet procedure locations. And speaking of surveys and surveyors, I also don’t think it would be unreasonable to think that this might very well be an imminent topic of conversation once November 5 rolls around and we begin our new compliance journey in earnest. Remember, there is what I will call an institutional tendency to focus on what has changed in the regulations as opposed to what remains the same. And I think that NFPA 99 is going to provide a lot of fodder for the survey process over the next little while. I mean think about it, we’re still getting “dinged” for requirements that are almost two decades old—I think it will be a little while before we get our arms (and staff) around the ins and outs of the new stuff. Batten down the hatches: Looks like some rough weather heading our way!

At any rate, here’s the link to the wet procedure location assessment tool.

Hope everyone has a safe and festively spooky (or spookily festive) All Hallows Eve!