November 01, 2016 | | Comments 0
Print This Post
Email This Post

History shows again and again how standards (and EPs) point out the folly of men…

It’s beginning to look like the proofreaders in Chicago must be enduring some late nights watching the Cubs! I don’t know about you folks, but I rely rather heavily on the regular missives from The Joint Commission, collectively known as Joint Commission E-Alerts. The E-Alerts deliver regular packages of yummy goodness to my email box (okay, that may be a little hyperbolic) and yesterday’s missive was no exception. Well, actually, there was an exception—more on that in a moment.

While it did not get top billing in the Alert (which seems kind of odd given what’s been going on this year), the pre-publication changes to the Life Safety chapter of the accreditation manual have been revealed, including comparison tables between what we had in January 2016 and what we can expect in January 2017. Interestingly enough, the comparison tables include the Environment of Care (EC) chapter stuff as well (though the EC chapter did not merit a mention in the E-Alert), so there’s lots of information to consider (which we will be doing over the course of the next little while) and some subtle alterations to the standards/EP language. For example (and this is the first “change” that I noted in reviewing the 112 pages of standards/EPs), the note for EC.02.02.01, EP 9 (the management of risks associated with hazardous gases and vapors) expands the “reach” to specifically include waste anesthetic gas disposal and laboratory rooftop exhaust (yes, I know…very sexy stuff!). It does appear that at least some of the changes (tough to figure out the split between what is truly “new” and what is merely a clarification of existing stuff—check out the note under EC.02.03.05, EP 1 regarding supervisory signal devices because it provides a better sense of what could be included in the mix). Another interesting change occurs under EC.02.03.05 (and this applies to all the testing EPs) is that where previously the requirement was for the completion dates of the testing to be documented, now the requirement actually states that the results of the testing are to be documented in addition to the completion dates. Again, a subtle change in the language and certainly nothing that they haven’t been surveying to. Oh, and one addition to the canon is the annual inspection and testing of door assemblies “by individuals who can demonstrate knowledge and understanding of the operating components of the door being tested. Testing begins with a pre-test visual inspection; testing includes both sides of the opening.” At any rate, I will keep plowing through the comparison table. (Remember in the old days, it would be called a crosswalk. Has the 21st century moved so far ahead that folks don’t know what a crosswalk is anymore?)

The top billing in yesterday’s All Hallows Eve E-Alert (making it an Eve-Alert, I suppose) went to the latest installment in that peppiest of undertakings, the Physical Environment Portal. Where the proofreaders comment comes into play is that the Alert mentions the posting of the information relative to LS.02.01.30, (which happened back in August) but when you click on the link, it takes you to the update page, where the new material is identified as covering LS.02.01.35, so there is updated material, though you couldn’t really tell by the Alert. So, we have general compliance information for the physical environment folks, some kicky advice and information for organizational leadership, and (Bonus! Bonus! Bonus!) information regarding the clinical impact of appropriately maintaining fire suppression systems (there is mention of sprinkler systems, but also portable fire extinguishers). I’d be interested to see if anyone finds the clinical impact information to be of particular use/effectiveness. I don’t know that compliance out in the field (or, more appropriately, noncompliance) is based on how knowledgeable folks are about what to do and what not to do, though perhaps it is the importance of the fire suppression systems and the reasons for having such systems (Can you imagine having to evacuate every time the fire alarm activates? That would be very stinky.) that is getting lost in the translation. I have no reason to think that the number of findings is going to be decreasing in this area (if you’re particularly interested, the comparison table section on LS.02.01.35 begins on p. 80 of that document—any changes that I can see do appear likely to make compliance easier), so I guess we’ll have to keep an eye on the final pages of survey year 2016 and the opening of the 2017 survey season. Be still my beating heart!

Entry Information

Filed Under: Environment of careLife Safety CodeThe Joint Commission

Tags:

Steve MacArthur About the Author: Steve MacArthur is a safety consultant with The Greeley Company in Danvers, Mass. He brings more than 30 years of healthcare management and consulting experience to his work with hospitals, physician offices, and ambulatory care facilities across the country. He is the author of HCPro's Hospital Safety Director's Handbook and is contributing editor for Briefings on Hospital Safety. Contact Steve at stevemacsafetyspace@gmail.com.